The changes in issue 224 of ESCC QUALIFIED PART LIST (QPL) are included in the DCR 1485 and detailed herein below:
Extension
(the validity date of the certificate is extended, and the scope is not changed, which means no new components are included):
The following list of certificates was extended:
- Certificate 140R from C&K (France). This certificate covers D-Shaped Connectors and Accessories based on type MDM included in detail specifications ESCC 3401/029, ESCC 3401/041, ESCC 3401/032, and ESCC 3401/087.
- Certificate 141R from C&K (France). This certificate covers PCB Connectors included in detail specification ESCC 3401/031.
- Certificate 276H from Exxelia SAS (France). This certificate covers Power Inductors based on series SESI and CMC included in detail specifications ESCC 3201/009 and ESCC 3201/010.
- Certificate 290F (page 46) from C&K (France). This certificate covers D-Shaped Connectors and Accessories based on type MDMA included in detail specifications ESCC 3401/077 and ESCC 3401/078.
Extension with re-scope:
- Certificate 71T from C&K (France). The qualified range has been extended, and now it will cover variants from 81 to 153 from ESCC 3401/072. This certificate affects D-Shaped Connectors and Accessories based on type D*M and includes detailed specifications ESCC 3401/001, ESCC 3401/004, ESCC 3401/022, ESCC 3401/040, and ESCC 3401/080.
- Certificate 72T from C&K (France). The qualified range has been extended, and now it will cover variants 01 and 02 (only 4 way) from ESCC 3401/097. This certificate affects D-Shaped Connectors and Accessories based on type D*MA and includes detailed specifications ESCC 3401/002, ESCC 3401/005, ESCC 3401/020, and ESCC 3401/021.
- Certificate 362A from Leach (France). The qualified range has been extended. Relays GP2 type are now included, variants 01 to 06 from ESCC 3602/003. This certificate affects Latching Electromagnetic Relays based on types GP250 and GP2 and also contains detailed specification ESCC 3602/010.
Related Articles
The GRACE project: Electrical characterization at 500°C
The GRACE project develops SiC radiation sensors for plasma diagnostics, tested at 500°C to ensure fusion reactor suitability.
Thermal Vacuum for HV Optocouplers
HV optocouplers require thermal vacuum testing to ensure isolation reliability, as vacuum can affect internal gel stability and performance.
SIC diodes versus Heavy Ions (SEE)
SiC diodes offer high-performance switching for space use, with radiation effects manageable through proper testing and bias control.