Skip to Content
  • Resources
    • COTS For Space WEBINARS
    • EEE Components
    • SPECIFICATIONS / QPLs
    • Events / Webinars
    • Space Talks
    • Tech Articles
    • Manufacturer Notifications
  • Electronic Design
  • Laboratory Services
    • Laboratory Standard Testing
    • Non Standard Testing
    • Silicon Carbide -SiC- Diodes
    • CrowdTesting
    • Optoelectronics
    • Small Sats
    • Representative Projects / Papers
  • Tools
    • Comparator
    • MYDCLs / BOMs
    • esa-stockplace
  • About Us
  • Proposal Next
  • Sign In
Cookies on the doEEEt website. We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we'll assume that you are happy to receive all cookies on the doEEEt website. However, if you would like to, you can change your cookie settings at any time. Link to cookies policy.
doEEEt DPA Test for Power Filters ICs | doEEEt.com
  • Home
  • How does doEEEt works
  • About us
  • Contact Us
  • Terms of Use
  • Disclaimer
  • Privacy Policy
  • Privacy Policy and Legal Notice
  • Cookie Policy
  • Copyright
  • autosignup2
  • Instant Quote
  • Introducing NanoXplore And Its European FPGA’s ITAR Free
  • Space Talks 3 - Dan Friedlander
  • autosignup3
  • Shopping Cart
  • wpo
  • Data Protection
  • Components
  • Documents
Please enter at least one character to search
ALTER Laboratory Services
Servicio Familia Servicio Familia
Image
Image

DPA Test for Power Filters ICs

Destructive Physical Analysis (DPA test) is a systematic, logical, detailed examination of EEE parts at various stages of physical disassembly. This activity is performed in order to verify that the manufactured lot quality is in accordance with the detailed specification and project requirements. Anomalies and defects detected through DPA could cause degradation or failure of the system in which the devices are to be employed. >> Read more

Fill the form to receive expert assistance from our skilled engineers and technicians

Read Policy

Related content

analysis of material

Material Analysis Techniques for Electronic Components

X-Ray Inspection applied to DPA test

DPA Test

Advances in Packaging and EEE Components

Destructive Physical Analysis (DPA) of EEE Components

Updates of ESCC 21001: Destructive Physical Analysis (DPA) of EEE Components

EEE Parts Results Page

DPA Test for Power Filters ICs

Destructive Physical Analysis (DPA test) is a systematic, logical, detailed examination of EEE parts at various stages of physical disassembly. This activity is performed in order to verify that the manufactured lot quality is in accordance with the detailed specification and project requirements. Anomalies and defects detected through DPA could cause degradation or failure of the system in which the devices are to be employed. >> Read more

EEE Parts Results Page

Applications expected requirements
Category
Category
Recommended
More...
Close
  • Microcircuits
    • Power Management
      • Filter

194 results found for Filter/Power Management/Microcircuits

Reset
Part reference
Quality level / QPL
TOP
Package
TID (krads)
SEE (MeV/mg/cm2)
DC Resistance [Max]
Input Voltage [Max]
Input Voltage [Min]
Noise Reduction [Min]
Unit price
Lead time

98026-01HYA
AME270461Y/CH
International Rectifier HIREL an Infineon Company
DWG_98026

Compare DCL / BOM Cart
QML H
Qualified
QPDSIS-38534
-55ºC to +125ºC
Surface Mount
CFP-12
400mOhm
400V
-400V
60dB @f=500kHz ; f=1MHz

10018-01HTC
FMCE-1528-W/883
Interpoint
10018

Compare DCL / BOM Cart
QML H
Qualified
QPDSIS-38534
-55ºC to +125ºC
Through Hole Mount
Hybrid PKG-12 (Flanged, Lead Form Up)
70mOhm
50V
-0,5V
60dB @f=500kHz ; f=1MHz

00002H01KXC
SFME120-461/KH
Interpoint
DWG_00002

Compare DCL / BOM Cart
QML K
Not qualified
QPDSIS-38534
-55ºC to +125ºC
Point to Point Wiring
Hybrid PKG-12 (Flanged)
TID (HDR): 1000.0
600mOhm
180V
80V
60dB @f=1MHz ; f=5MHz

13010-01KXA
SVRMC28K-E
VPT Inc
13010

Compare DCL / BOM Cart
QML K
Qualified
QPDSIS-38534
-55ºC to +125ºC
Through Hole Mount
Hybrid DIP-5
150mOhm
40V
0V
40dB @f=500kHz

5962-8864101RA
MTLTC1060AQD
Micross Components
5962-88641

Compare DCL / BOM Cart
QML Q
Qualified
QPDSIS-38535
-55ºC to +125ºC
Through Hole Mount
CDIP-20

10015-01HXA
FMCE-0328/883
Interpoint
10015

Compare DCL / BOM Cart
QML H
Qualified
QPDSIS-38534
-55ºC to +125ºC
Through Hole Mount
Hybrid DIP-5
250mOhm
50V
-0,5V
50dB @f=500kHz

95003-01HZC
FMH-461F/883
Interpoint
DWG_95003

Compare DCL / BOM Cart
QML H
Qualified
QPDSIS-38534
-55ºC to +125ºC
Through Hole Mount
Hybrid DIP-5 (Flanged)
350mOhm
40V
16V
55dB @f=500kHz

95004H03KXA
SFME28-461/KH
Interpoint
DWG_95004

Compare DCL / BOM Cart
QML K
Qualified
QPDSIS-38534
-55ºC to +125ºC
Point to Point Wiring
Hybrid PKG-12 (Flanged)
TID (HDR): 1000.0
70mOhm
40V
16V
60dB @f=500kHz ; f=1MHz

98027-01HZA
AME28461Z/CH
International Rectifier HIREL an Infineon Company
DWG_98027

Compare DCL / BOM Cart
QML H
Qualified
QPDSIS-38534
-55ºC to +125ºC
Surface Mount
CFP-12
40mOhm
40V
-40V
60dB @f=500kHz ; f=1MHz

94010H02KZC
SFMC28-461F/KH
Interpoint
DWG_94010

Compare DCL / BOM Cart
QML K
Qualified
QPDSIS-38534
-55ºC to +125ºC
Through Hole Mount
Hybrid DIP-5 (Flanged)
TID (HDR): 1000.0
200mOhm
40V
16V
55dB @f=500kHz
Part validation activities
Cost & Activity Matrix
  • <
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • >
Alter Technology Laboratory Services
  • Screening
  • Evaluation/Qualification
  • Scanning Acoustic Microscopy
  • RF/Microwave
  • Incoming Inspection
  • DPA

EEE Components
  • Capacitors
  • Microcircuits
  • Resistors
  • Crystals and Oscillators
  • Schottky Barrier Rectifiers
  • Discretes

Laboratory Success Cases
  • GRACE Project
  • XRAY, SAM and Cross Section
  • SiC schottky Diode
  • JUICE Case
  • Deimos Neptuno
  • Melissa III

Company
  • About Us
  • Contact-us
  • How does doEEEt works?
Security & Privacity
  • Privacy Policy and Legal Notice
  • Copyright
  • Cookie Policy
  • Contact Clause
  • LinkedIn LinkedIn
  • Twitter Twitter
Copyright © 2023 ALTER TECHNOLOGY TÜV NORD S.A.U
All rights reserved.